Home » SiliFlex Wire & Cable
SiliFlex Wire & Cable

Calmont has some overstock in finished Siliflex Single Conductor Wires Click here for more information
Calmont supplies SiliFlex wire and cable, an ultra-fine, limber stranded construction insulated by Silicone rubber and distinguished by its extreme limpness and flexibility
Inherently soft and pliable, SiliFlex wire and cable can be tailored for a variety of applications such as extreme low temperature flexibility, extreme heat resistance, optimum radiation and flame resistance and high strength and purity.
| FEATURES |
APPLICATIONS |
- Resistant to temperature extremes
- Excellent electrical properties
- Easily stripped
- Light weight
- Corona resistant
- High radiation resistance
|
- Pliable and flexible even in the high voltage and high altitude conditions of aerospace
- Extremely suitable for biomedical use where flexible instrumentation cables are needed. A type of SiliFlex is available that will meet FDA standards
- Robotic and sensor cables requiring flexibility and low noise
|
| Electrical Properties |
DC Volume Resistivity (ohm-CM) |
1 x 1015 |
| Dielectric Strength (VPM on .075 slab) |
550 - 700 |
| Dielectric Constant at 60 Hz |
2.9 - 3.5 |
| Power Factor at 60 Hz |
0.002 - 0.004 |
| Radiation Resistance (Roentgens) |
1 x 108 |
| Physical Properties |
Specific Gravity |
1.20 - 1.45 |
| Elongation (%) |
125 (min.) |
| Shore Hardness (A Scale) |
65 (average) |
| Tensile Strength (PSI) |
800 - 1,100 |
| Thermal Properties |
Temperature Rating |
-73°C to 204°C (-100°F to 400°F) |
Estimated Useful Life at:
| |
-62°C (-80°F)
121°C (250°F)
149°C (300°F)
204°C (400°F)
260°C (500°F)
|
|
Indefinite
10 years
5 years
2 years
3 months |
| Flame Resistance |
Siliflex is available with a self-extinguishing Silicone rubber insulation that will pass the Underwriter's Laboratories® VW-1 flame test and the 45° angle flame test of MIL-W-16878 |
| Medical Usage |
SiliFlex made with medical grade Silicone rubber—compounded under clean room conditions—can be used for medical implantation. To maintain the highest level of purity, non-pigmented insulation is available. |
|